6.11.3
{{sendMatomoQuery("Sangfor Cloud Platform (SCP)","Shared Mode")}}

Shared Mode

{{ $t('productDocDetail.updateTime') }}: 2025-12-18

Step 1: Login HCI go to Nodes > Physical Interfaces locate the aggregation interface click Edit check Enable storage network interface multiplexing.

Step 2: Under Nodes > Physical Interfaces click Add Multiple VLAN Subinterfaces select the Physical aggregation Interfaces, leave the IP and VLAN information blank.

Step 3: Go to Nodes > Communication Interfaces > Storage Network Interface click Storage Area Network Settings.

Step 4: Select interface

Select one physical aggregation interface, fill in the VLAN id.

Step 5: Configure interface IP.

The HCI system will automatically assign an IP address and the corresponding subnet mask to the network interface. You can replace the default IP address with the planned IP address by directly entering it in the input box and adjusting the IP address subnet mask by clicking the Configure Netmask button.

Step 6: Confirm information.

Confirm all the information is correct then click the OK button to complete the process.