Hyper Converged Infrastructure (HCI/aSV)

Sangfor HCI and aSV provide a unified infrastructure combining compute, storage, networking, and built-in security to simplify deployment, operations, and services.
{{ $t('productDocDetail.guideClickSwitch') }}
{{ $t('productDocDetail.know') }}
{{ $t('productDocDetail.dontRemind') }}
6.11.1R1
{{sendMatomoQuery("Hyper Converged Infrastructure (HCI/aSV)","HCI Pre-Upgrade Check")}}

HCI Pre-Upgrade Check

{{ $t('productDocDetail.updateTime') }}: 2026-01-15

One week before upgrading HCI for a customer, please visit the customer or establish a remote connection to check whether the customer's environment meets the upgrade requirements using the pre-upgrade check package. This will help facilitate the subsequent upgrade process and does not require downtime. Make sure a pre-upgrade check is done before an official upgrade. If the pre-upgrade check for an official upgrade fails, it is recommended to reschedule for the upgrade.

Step 1.Use aDeploy to perform a pre-upgrade check and wait for the check to complete. Click Details next to the failed entities and handle them according to the solutions. Perform the pre-upgrade check again until all the entities pass the check.

SP pre-installation check is prohibited after the pre-upgrade check. Else, HCI will request you to run the pre-upgrade check again.

A screenshot of a computer

Description automatically generated

Step 2.After all the entities pass the check, click Install and wait for the installation to complete. A screenshot of a computer

Description automatically generated

A screenshot of a computer

Description automatically generatedA screenshot of a computer

Description automatically generated

  1. Troubleshooting instructions
  1. For an offline upgrade, a message will be displayed after the pre-upgrade check is completed, indicating that a VM is running on the node. You may ignore this message temporarily. Before an official upgrade, all virtual devices must shut down and run a pre-upgrade check again.
  2. If the pre-upgrade check fails and a message indicates the pre-upgrade check failure, please contact a Sangfor technical support representative.
  3. If a clustered node fails the pre-upgrade check and the pre-upgrade check does not proceed for more than 10 minutes, please contact a Sangfor technical support representative.
  4. In versions earlier than HCI6.9.0, VM names can only contain digits, spaces, letters, Chinese characters, and special characters (()【】_-.+()@). Invalid VM names will cause the pre-upgrade check to fail.